Emergency thermostat (self-acting)
- Add feedback:
- Symbol produktu: 054
Menu: Emergency thermostat (self-acting)
Description
Element designed for mechanical protection of the boiler. Its purpose is to disconnect the feeder or blower supply circuit as a result of too high temperature in the boiler. It works on the principle of disconnecting contact. The contacts disconnect when a certain (alarm) temperature is exceeded, which results in breaking the circuit. It is an automatic element, i.e. when the temperature drops below a certain threshold (usually 60 ˚C), the thermostat contacts close again. This thermostat is available in a tube or a box.
Special features
Characteristics | |
Housing type | Tube or can |
Temp. contact disconnection | 95 ˚C |
Cable length | 1,5m(tube) lub 3m(can) |
Cable color and type | Black silicone |
Regulators |
tube -Proton (seria 300), Krypton (seria 300), Krypton CWU, Argon 2/3/P, Titanic, Titanic +, Iryd, Yeti/Radon can - Krypton B, Argon 110 |
Mounting method
Installation on the outlet pipe from the boiler